Pet Drying Box Buyer Acceptance Test
This page is a buyer acceptance-protocol template, not a NAVORIQ test report. The buyer and supplier should first agree the exact model, version, destination, test method and pass criteria, then record what was actually inspected on the approved sample or shipment.
Take the checklist into your supplier review.
Use the evidence and model fields as a cover sheet before agreeing a detailed drying-box acceptance protocol.
PDF · 1 page · EnglishDownload PDF ↓1. Freeze the model and written specification
Record the supplier model, hardware revision, destination voltage and plug, ordered color, included accessories and approved sample reference. A result is meaningful only when it can be tied to the same configuration that will be shipped.
- Model and revision
- Destination and electrical configuration
- Approved sample or specification reference
- Quantity and inspection lot
- Packing and label version
2. Check identity, ratings and physical condition first
Photograph the product, rating label, accessories and packaging before a functional check. Compare dimensions, weight and stated materials with the agreed specification, and record any difference rather than silently accepting a near match.
3. Agree an empty-chamber functional check
For an initial buyer inspection, use an empty chamber. Agree temperature measurement points, stabilization time, operating mode, test duration and instrument details in writing. Record control response, airflow at the agreed points, display or button behavior, door response and normal stop behavior.
- No pet is used as a test load
- Ambient conditions and instrument IDs are recorded
- Temperature points and duration are agreed in advance
- Unexpected odor, vibration, noise or shutdown is documented
- Any retest uses the same method
4. Treat manual-listed functions as claims to verify
A supplier manual can identify what should be checked, but it is not the same as an independent result. For a listed noise figure, record distance, background noise, operating mode and instrument. For airflow, protection, UVC or negative-ion functions, request the applicable method or report and verify the agreed function on the sample where practical.
5. Close packing, documents and disposition
Match the unit, accessories, labels, manual and packing to the approved version. Finish with one written disposition: Pass, Conditional, Retest or Reject. Every condition should name the evidence, owner and deadline required before shipment approval.
LQ-HG100 source-record baseline
These fields come from the current NAVORIQ product record. They identify what to compare; they do not prove a production unit has passed inspection.
| Field | Current source record | Buyer acceptance treatment |
|---|---|---|
| Product identity | LQ-HG100 smart pet drying box; 68L. | Match the model, chamber description and ordered revision to the sample and rating label. |
| Size and construction | 43 × 46 × 47 cm; ABS and tempered glass. | Record actual dimensions, visible condition and any material or finish difference. |
| Weight | Net / gross weight 7.85 / 9.35 kg. | Agree tolerance and weighing method before using weight as an acceptance criterion. |
| Electrical rating | 220V, 50Hz, 1000W. | Confirm the ordered destination configuration and photograph the actual rating label. |
| Temperature | 22–45°C control range is listed. | Agree setpoints, measurement locations, duration, ambient conditions and tolerance in writing. |
| Manual-listed functions | Six-side airflow, 35dB, six protections, UVC and negative ions are listed in the source material. | Request the applicable method or report and verify only against an agreed sample protocol; do not treat the list as a completed test result. |
Certification, safety approval, performance, MOQ, lead time and final commercial terms are not established by this table.
Buyer acceptance record
Use one row per agreed requirement and keep the supporting photo, reading or document under the same evidence ID.
| Inspection item | Buyer specifies before test | Supplier or inspector records | Disposition |
|---|---|---|---|
| Identity and rating label | Exact model, revision, voltage, frequency, power, plug and label language. | Photograph and evidence ID; differences from the order. | Pass / Conditional / Retest / Reject |
| Dimensions, weight and finish | Measurement method, tolerances and approved appearance sample. | Measured values, instrument and defect photos. | Pass / Conditional / Retest / Reject |
| Empty-chamber temperature | Modes, setpoints, probe locations, ambient range, duration and tolerance. | Time-stamped readings and instrument ID. | Pass / Conditional / Retest / Reject |
| Airflow and controls | Agreed checkpoints, door/control response and normal stop sequence. | Observed response, video or photo evidence and exceptions. | Pass / Conditional / Retest / Reject |
| Noise | Operating mode, distance, room/background level, meter and tolerance. | Measured result with the full method—not a number alone. | Pass / Conditional / Retest / Reject |
| Packing and documents | Accessories, manual, label, protection, carton marks and requested evidence. | Count, version, packing photos and missing items. | Pass / Conditional / Retest / Reject |
The buyer and supplier must define the method and pass criteria. NAVORIQ does not create an unagreed safety or performance threshold through this template.